Configuring the controller
by running serveraid manager in startable cd mode, you can configure the controller before you install your operating system. the information in this section assumes that you are running serveraid manager in startable cd mode.

    to run the serveraid manager program in startable-cd mode, turn on the computer; then, insert the ibm serveraid support cd into the cd-rom drive. if the serveraid manager program detects an unconfigured controller and ready drives, the program automatically starts the configuration wizard.

    to run the serveraid manager program in startable-cd mode, turn on the computer; then, insert the ibm serveraid support cd into the cd-rom drive. if the serveraid manager program detects an unconfigured controller and ready drives, the program automatically starts the configuration wizard.

    using express configuration

    complete the following steps to use express configuration:

    1. in the serveraid manager tree, click the controller that you want to configure.

    2. from the toolbar, click create.

    3. click express configuration.

    4. click next. the “configuration summary” window opens.

    5. review the information that is displayed in the “configuration summary” window. to change the configuration, click modify arrays or modify logical drives.

    some operating systems have size limitations for logical drives. before you save the configuration, verify that the size of the logical drive is appropriate for your operating system.

    6. click apply; then, click yes when asked if you want to apply the new configuration. the configuration is saved in the controller and in the physical drives.

    7. exit from the serveraid manager program and remove the cd from the cd-rom drive.

    8. restart the computer.

    using custom configuration

    complete the following steps to use custom configuration:

    1. in the serveraid manager tree, click the controller that you want to configure.

    2. from the toolbar, click create.

    3. click custom configuration.

    4. click next. the “create arrays” window opens.

    5. click the appropriate tab in the right pane; then, from the list of ready drives, select the two drives you want to move to the array.

    6. click the icon to add the drives to the array.

    7. complete the following steps if you want to configure a hot-spare drive: a. click the spares tab. b. select the physical drive you want to designate as the hot-spare drive; then, click the icon to add the drive.

    8. click next. the “configuration summary” window opens.

    9. review the information that is displayed in the “configuration summary” window. to change the configuration, click back.

    10. click apply; then, click yes when asked if you want to apply the new configuration. the configuration is saved in the controller and in the physical drives.

    11. exit from the serveraid manager program, and remove the cd from the cd-rom drive.

    12. restart the computer.

   