Using LEDs to Identify Startup Problems
all system states in the startup sequence are indicated using leds. by checking the leds, you can determine when and where the system failed in the startup sequence. if you have problems after the switch is on, refer to the configuration procedures in the software configuration guide for your switch.

    after you connect the power cords to your catalyst 4500 series switch, follow these steps to determine whether your system is operating properly:

    step 1 check the power supply leds:

    1 the led labeled good should turn green when power is applied to the supply. the led should remain on during normal system operation.

    2 if the led labeled good does not light, or if the led labeled fail lights, see the “troubleshooting the power supply” .

    if a power supply is installed and not connected to a power source, power supply leds will indicate a failure.

    step 2 listen for the system fan assembly. if you do not immediately hear it begin to operate, see the “troubleshooting the fan assembly”.

    step 3 check that the leds on the supervisor engine light as follows:

    1 the led labeled status flashes orange once and stays orange during diagnostic boot tests.

    1.it turns green when the module is operational (online).

    2.if the system software is unable to start up, this led stays orange.

    3.if the led labeled status on the supervisor engine front panel is red or orange, connect a console to the management port and use the show environment command to check for possible problems. for more information, see the “troubleshooting supervisor engines”.

    2 the ethernet management port led turns green when the module is operational (online) and a link is established with another network device. if no signal is detected, the led labeled link turns off.

    step 4 verify that the leds labeled status on each switching module are green when the supervisor engine completes initialization.

    this led indicates that the supervisor engine and switching modules are receiving power, have been recognized by the supervisor engine, and contain a valid flash code version. however, this led does not indicate the state of the individual interfaces on the switching modules. if an led labeled status is red or orange, try reseating the switching module or supervisor engine and restarting the switch. if the problem persists, contact cisco tac. see the “contacting the cisco technical assistance center”.

    step 5 if the boot information and system banner are not displayed, verify that the terminal is set for 9600 baud, 8 data bits, no parity, and 1 stop bit and connected properly to the console port.

   