AFETY INFORMATION
please read the following safety information carefully before installing the baseline 10/100 switch.

    ATTENTION:installation and removal of the unit must be carried out by qualified personnel only.

    if installing the switch unit in a stack with superstack 3 hub units, the baseline 10/100 switch unit must be installed below the narrower hub units.

    the unit must be connected to an earthed (grounded) outlet to comply with international safety standards.

    do not connect the unit to an a.c. outlet (power supply) without an earth (ground) connection.

    the appliance coupler (the connector to the unit and not the wall plug) must have a configuration for mating with an en60320/iec320 appliance inlet.

    the socket outlet must be near to the unit and easily accessible. you can only remove power from the unit by disconnecting the power cord from the outlet.

    this unit operates under selv (safety extra low voltage) conditions according to iec 60. the conditions are only maintained if the equipment to which it is connected also operates under selv conditions.

    only connect an advanced redundant power system (3c16070, 3c16071, 3c16071a or 3c16071b) or redundant power system (3c565047) to the redundant power system socket.

    france and peru only

    this unit cannot be powered from it■ supplies. if your supplies are of it type, this unit must be powered by 230v (2p+t) via an isolation transformer ratio 1:1, with the secondary connection point labelled neutral, connected directly to earth (ground). ■ impédance à la terrere

    power cord set

    this must be approved for the country where it will be used. e.g.

    u.s.a. and the cord set must be ul-approved and csa certified.

    canada the minimum specifications for the flexible cord are:

    no. 18 awg

    type sv or sj

    3-conductor

    the cord set must have a rated current capacity of at least

    10a.

    the attachment plug must be an earth-grounding type

    with a nema 5-15p (15a, 125v) or nema 6-15p (15a,

    250v) configuration.

    denmark the supply plug must comply with section 107-2-d1,

    standard dk2-1a or dk2-5a.

    switzerland the supply plug must comply with sev/ase 1011.

    uk _ the supply plug must comply with bs1363 (3-pin 13-amp)

    and be fitted with a 5a fuse which complies with bs1362.

    the mains cord must be [har] or [basec] marked and

    be of type ho3vvf3go.75 (minimum).

    europe the supply plug must comply with cee7/7 ("schuko")

    the mains cord must be [har] or [basec] marked and

    be of type ho3vvf3go.75 (minimum).

   

   