SCANNER PARTS


    green and red led

    when the red led is on, this indicates that the laser is on. when the green led flashes on, the scanner has read a bar code successfully. when the green light turns off, communication to the host is complete. the green led blinks while the scanner is waking up from an ir sensor timeout. the led's are also used as diagnostic indicators and mode indicators.

    output window

    laser light emits from this aperture.

    adjustable stand

    designed to provide an adequate distance for scanning between the scanner face and counter at all times. when fully tilted, the face of the scanner remains a full five inches from the counter. refer to page 10 for available kits.

    cable

    this cable is terminated with a 10-pin modular connector, which attaches to the mca951. the keyboard wedge unit has a "y" coil cable terminated with a 5-pin female on one end, a 6-pin male and a 4-pin locking connector for power input (power jumper). an adapter is included with a 5-pin male din on one end and a 6pin female mini din on the other to mate to a specific keyboard. refer to appendix c for pin assignments.

   

   