1. turn off the host system.
2. disconnect the keyboard from the host.
3. connect the powerlink cable to the 2↑nd jack from the top of the ms7600.
4. connect the other end of the powerlink cable to the keyboard port on the host.
before continuing verify that the powerlink cable is connected to the appropriate interface jack on the scanner. an incorrect cable connection can cause communication problems or potential damage to the scanner.
5. connect the external power supply to the power jack on the powerlink cable.

figure 15: stand-alone keyboard interface
6. check the ac input requirements of the power supply to make sure the voltage matches the ac outlet.
7. connect ac power to the transformer.
the outlet should be near the equipment and easily accessible.

8. scan the load keyboard wedge defaults bar code then the enable stand alone keyboard bar code to configure the ms7600 for stand-alone keyboard communication.
when scanning the bar codes, cover the code not being scanned to ensure the codes are read in the proper sequence.

9. turn on the host system.
1.to maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for selv (safety extra low voltage) according to en 60950.
2.to maintain compliance with standard csa c22.2 no. 60950-00/ul 60950 and norm en 60950, the power source should meet applicable performance requirements for a limited power source.