System Power-On Methods
this section discusses the following system power-on methods:

    1 power-on switch

    2 service processor menus

    privileged users can power on the system by selecting the system control power menu option from the main menu and then selecting the power-on system option from the system power control menu. general users should select power-on system on the general user menu.

    3 remote power-on via ring-indicate signal

    the server automatically powers on when it detects a 2ring indicate2 signal from a modem attached to serial port 1 (s1) or serial port 2 (s2).

    a remote user can call the server to activate ring detection by the modem. listen for a few more rings than the threshold number for starting the system. the system powers on without answering the call.

    4 unattended start mode - refer to enable/disable unattended start mode on page 40.

    the service processor can be enabled to recover from the loss of ac power (see enable/disable unattended power-on mode in the system power control menu). when ac power is restored, the system returns to the power state at the time ac loss occurred. for example, if the system was powered on when ac loss occurred, it reboots/restarts when power is restored. if the system was powered off when ac loss occurred, it remains off when power is restored.

    5 timed power-on - refer to the shutdown -t command on servers using aix.

    working in conjunction with aix, the service processor in your server can operate a timer, much like the wake-up timer on your clock radio. you can set the timer so that your server powers on at a certain time after shutting down. the timer is battery-operated, so power interruptions that occur while the server is off do not affect its accuracy. refer to the aix shutdown -t command for details on setting the timer.

    if an ac power loss is in progress when the timed power-on attempt occurs, the server cannot power on when ac power is restored.

    6 follow-up to a failed boot attempt

    the service processor initiates a power-on sequence if a failed boot attempt is detected (due to a hardware or software failure).

    7 fast or slow boot (ipl)

    using the service processor menus, you can select the ipl type, mode, and speed of your system.

    selecting fast ipl results in several diagnostic tests being skipped and a shorter memory test being run.

   

   