Clearing L3 Gard Records
the following menu should be accessed only by a customer engineer after an l3 cache module is replaced.

    to reset clear the l3 module gard records, perform the following steps:

    1. at the service processor main menu, enter the access code 85712. a screen similar to the following is displayed.

   

    2. press enter. the following text is displayed at the bottom of the screen:

   

    3. enter y to clear the records. a task completed message is displayed.

    if ″n″ is entered, the ″(press return to continue)″ message is displayed and the l3 gard records are not cleared.

    this step ends the procedure for clearing the l3 gard records.

   

   