Disturbance or System Attention LED
the system attention led on the operator panel is turned on when an entry is made in the service processor error log that gets transmitted to the system-level error logs (the aix error log and the service action event log in service focal point). when the attention light comes on, examine these error logs to see if user intervention is required.

    if a hardware problem is indicated, call service support. if no intervention is required, the system attention led can be turned off by either of the following methods:

    1 on the hmc’s graphical interface, as follows:

    1. click on the service applications icon.

    2. double-click the service focal point icon.

    3. in the contents area, select hardware service functions. the led management window opens.

    4. in the led management window, select one of more managed systems from the table.

    5. select deactivate led. the associated system attention led is turned off.

    for more information about the operator panel as it relates to the hmc, see the ibm hardware management console for pseries installation and operations guide, order number sa38-0590.

    2 as a user with root authority, enter diag on an aix command line and do the following:

    1. select task selection.

    2. on the task selection menu, select identify and attention indicators.

    3. when the list of leds displays, use the cursor to highlight set system attention indicator to normal.

    4. press enter, and then press f7 to commit. this action turns off the led.

    3 if the system is powered off, access the service processor menus and from the main menu do the following:

    1. select system information menu.

    2. select led control menu.

    3. select clear system attention indicator. this will turn the led off.

    for more information regarding the led, refer to chapter 3, “using the service processor” on page 15.

   

   