Media and Ribbon Calibration
initially, you may want to try autocalibrating the printer rather than proceeding with the full calibration procedure described below. to autocalibrate the printer:

    1. load the media and ribbon.

    2. close the printhead. the printer autocalibrates.

    if the media fails to load or an error occurs, then perform the steps listed below.

    all steps must be performed in the following procedure, even if only one sensor needs to be adjusted.

    1. press the setup/exit key.

    2. press the next/save key until “media and ribbon calibrate” displays.

    3. press the (+) key to start the calibration sequence. “load backing cancel continue” displays.

    4. open the printhead. remove approximately 8" (200 mm) of labels from the media roll, enough so that only the backing material is threaded between the media sensors when the media is loaded (refer to figure 10).

   

    5. press the (+) key. the front panel display shows “remove ribbon cancel continue.”

    6. slide the ribbon as far from the printer frame as possible.

    7. close the printhead, trapping the ribbon in this position.

    8. press the (+) key. the front panel shows “calibrating please wait.”

    9. when this part of the calibration process is completed, the display reads “reload all continue.”

    10. open the printhead. pull the backing material until a label is positioned between the media sensors.

    11. return the ribbon to its proper position.

    12. close the printhead. press the (+) key to perform the next part of the calibration sequence. “media and ribbon calibrate” displays. the printer is calibrated when the media stops feeding.

    13. press the setup/exit key to leave the programming mode. choose “permanent” when save changes displays.

    14. press the next/save key to save the changes.

   