many printer settings may also be controlled by your printer's driver or label preparation software. please refer to the driver or software documentation for more information.
all steps must be performed in the following procedure, even if only one sensor needs to be adjusted.
1. press the setup/exit key.
2. press the next/save key until “media and ribbon calibrate” displays.
3. to start the calibration procedure, press the right black oval key. “load backing cancel continue” displays.
4. open the printhead. remove approximately 8" (200 mm) of labels from the media roll, enough so that only the backing material is threaded between the media sensors when the media is loaded (refer to figure 11).

5. press the right black oval key. the front panel display shows “remove ribbon cancel continue.”
6. either remove the ribbon or slide it as far from the printer frame as possible.
7. close the printhead, trapping the ribbon in this position.
8. press the right black oval key. the front panel shows “calibrating please wait.”
9. when this part of the calibration process is completed, the display reads “reload all continue.”
10. open the printhead. pull the backing material until a label is positioned between the media sensors.
11. either load the ribbon or return the ribbon to its proper position.
12. close the printhead. press the right black oval key to perform the next part of the calibration sequence. “media and ribbon calibrate” displays. the printer is calibrated when the media stops feeding.
13. press the setup/exit key to leave the programming mode. choose “permanent” when save changes displays.