Performing a Bar Code Read Operation
1 press the [pw] key to turn power on. hold the data collector close to the bar code and press the trigger key.

   

    2 the reader port emits a laser to read the bar code. the read indicator lights green when the read is successful.

   

    1 if you have problems with the read operation, change the angle between the label and data collector, or move closer and then try again.

    2 if the bar code is larger than the diameter of the data collector's reader port, try moving the data collector a bit farther away from the bar code.

    3 the data collector should be able to read a bar code from the maximum distance of 38 centimeters on the forward-facing reader port model and about 30 centimeters on the down-facing reader port model under the following conditions.

    ambient light: 500 lux (fluorescent)

    pcs: 0.9 min.

    minimum bar width: 1.2 mm

    itf (extended version)

   

    1 wavelength: 650 nm

    maximum output: 1.0 mw

    2 caution

    use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

   