DSP ALM
purpose

    display the contents of the alarm buffer. this buffer can contain up to 100 alarms.

    syntax

    dsp alm [option]

    use

    1. to display the complete contents of the buffer, type:

    dsp alm[enter]

    2. to display only the last alarm of each type, type:

    dsp alm /l[enter]

    3. to display the complete buffer contents and then clear all the on-type alarms (i.e. change their status to off), type:

    dsp alm /c[enter]

    4. to display the complete buffer contents and then clear all the alarms, type:

    dsp alm /ca[enter]

    the contents of the alarm buffer are displayed as a table with four columns: the alarm record number, alarm description, alarm status, and time of occurrence.

    the explanation of the on and on/off alarm types is given in section 5.2.

    table 4-5 lists all the alarm messages that can be displayed by the terminal.

   

   

   