Starting the System Without an HMC Attached
to power on the system, do the following:

    1. on a model 6c3, open the front rack door.

    on a model 6e3, open the bezel door.

    2. before you press the power button on your operator panel, observe the following:

    1 the power led is slowly blinking.

    2 an ok prompt is visible in the operator panel display.

   

    3. press the power-on button on the operator panel.

    after you press the power button located on the operator panel, observe the following:

    a. the power led begins to blink visibly faster.

    b. the system cooling fans are activated and can be heard accelerating to operating speed.

    there is approximately a 30-second transition period between the time the power button is pressed and the power led remains on solid (no longer blinking).

    c. the power led stays on solid. progress indicators, also referred to as checkpoints, are visible on the operator panel display.

    if you just completed installing the system, run system verification. refer to “step 27. run system verification” on page 38. if not, go to “step 26. access the system documentation” on page 38

   